Fa'asinoga Tulaga | Suafa |
EN 60601-2-54:2009 | Meafaigaluega eletise faʻafomaʻi - Vaega 2-54: Manaoga faʻapitoa mo le saogalemu ma le faʻatinoina o mea faʻaoga X-ray mo le leitio ma le leitio |
IEC60526 | Poloka uaea maualuga ma socket so'oga mo masini X-ray faafomai |
IEC 60522:1999 | Fuafuaga o le fa'amama tumau o fa'aputuga paipa X-ray |
IEC 60613-2010 | Eletise, vevela ma le utaina o uiga o le rotating anode X-ray tubes mo suʻesuʻega faafomaʻi |
IEC60601-1:2006 | Meafaigaluega eletise fa'afoma'i - Vaega 1: Mana'oga lautele mo le saogalemu ma le fa'atinoga taua |
IEC 60601-1-3:2008 | Meafaigaluega eletise faʻafomaʻi - Vaega 1-3: Manaoga lautele mo le saogalemu faʻavae ma faʻatinoga taua - Tulaga Faʻamaonia: Puipuiga faʻavevela i mea faʻataʻitaʻi X-ray |
IEC60601-2-28:2010 | Meafaigaluega eletise faʻafomaʻi - Vaega 2-28: Manaoga faʻapitoa mo le saogalemu ma le faʻatinoga taua o faʻalapotopotoga faʻapipiʻi X-ray mo suʻesuʻega faafomaʻi. |
IEC 60336-2005 | Meafaigaluega eletise faʻafomaʻi-X-ray tube faʻapotopotoga mo suʻesuʻega faʻafomaʻi-Uiga o nofoaga taulaʻi |
●O le igoa e fatuina e faapea:
MWHX7110A | Faila | A | Socket eletise maualuga ma le 90 tikeri faʻatonuga |
MWTX71-0.6/1.2-125 | B | Socket eletise maualuga ma le 270 tikeri faʻatonuga |
Meatotino | Fa'amatalaga | Tulaga | |
Malosi'i fa'aigoa (s) o le anode | F 1 | F 2 | IEC 60613 |
20kW(50/60Hz) | 40kW(50/60Hz) | ||
Anode le gafatia e teu ai vevela | 110 kJ ( 150kHU) | IEC 60613 | |
O le maualuga o le malulu o le anode | 500W | ||
Malosiaga teu vevela | 900kJ | ||
Max. fa'amama fa'aauau le vevela e aunoa ma le Air-circular | 180W | ||
mea anodeAnode pito i luga mea e ufiufi ai | Rhenium-Tungsten-TZM(RTM) Rhenium-Tungsten-(RT) | ||
Ilo fa'atatau (Ref: axis reference) | 12.5 ° | IEC 60788 | |
X-ray fa'apipi'i fa'apipi'i fa'amama fa'atosina | 1.5 mm Al / 75kV | IEC 60601-1-3 | |
Tulaga fa'atatau taua | F1(tama'i taula'i) | F2(tulaga tele) | IEC 60336 |
0.6 | 1.2 | ||
X-ray paipa fa'ailoga eletiseRadiographicFluoroscopic | 125kV 100kV | IEC 60613 | |
Faʻamatalaga ile faʻamafanafanaina o cathode Max. taimi nei Max voltage | ≈ /AC, <20 kHz | ||
F1 | F 2 | ||
5.1A ≈7~9V | 5.1 A ≈12~14 V | ||
Leakage radiation ile 150 kV / 3mA ile 1m mamao | ≤0.5mGy/h | IEC60601-1-3 | |
Fa'asalaina pito maualuga | 443×443mm ile SID 1m | ||
X-ray paipa fa'apotopotoga mamafa | Pe tusa. 18 kilokalama |
Tapulaa | Tapulaa o Galuega | Felauaiga ma le teuina o tapula'a |
O le vevela o le siosiomaga | Mai le 10℃i le 40℃ | Mai- 20℃to 70℃ |
Susū fa'atusa | ≤75% | ≤93% |
Barometric pressure | Mai le 70kPa i le 106kPa | Mai le 70kPa i le 106kPa |
1-vaega stator
Su'ega su'ega | C-M | C-A |
Tete'e vili | ≈18.0…22.0Ω | ≈45.0…55.0Ω |
Max.fa'atagaina le galue malosi | 230V±10% | |
Fautuaina le eletise galue (fa'agasolo) | 160V±10% | |
Vaitaimi taofi | 70VDC | |
Volivili ta'avale i le fa'aaliga | 80Vrms | |
Voli fa'asolosolo ile fluoroscopy | 20V-40Vrms | |
Taimi fa'agasolo (fa'alagolago ile faiga amata) | 1.2s |
1. X-ray Radiationpuipuiga
O lenei oloa e faʻamalieina manaʻoga o le IEC 60601-1-3.
O lenei X-ray tube faʻapotopotoga emits X-ray radiation i le faʻagaioiga. Na o tagata agavaa ma aʻoaʻoina tutusa e faʻatagaina e faʻaogaina le faʻapotopotoga faʻapipiʻi X-ray.
O a'afiaga fa'aletino talafeagai e ono afaina ai le ma'i, e tatau i le gaosiga o masini ona faia se puipuiga talafeagai e aloese ai mai fa'avevela o le ionization.
2.Dielectric 0il
X-ray tube faʻapotopotoga o loʻo i ai le 0il dielectric mo le mautu maualuga. E pei o se mea oona mo le soifua maloloina o tagata,pe afai e fa'aalia i le nofoaga e le fa'asaina,e tatau ona lafoai e tusa ai ma tulafono faatonutonu a le lotoifale.
3. Siosiomaga o Galuega
E le fa'atagaina le fa'aogaina o le fa'aputuga fa'a-X-ray i le ea o le kasa e mu pe pala
4.Fetuuna'i le Tube Current
Fa'alagolago i tulaga fa'atino,e ono suia uiga filament.
O lenei suiga e ono o'o atu ai i le ova atu o le fa'aalia i le fa'aputuga fa'aigoa X-ray.
Ina ia puipuia le fa'aputuga paipa X-ray mai le faaleagaina,fetuutuunai le faagaau pea.
E le gata i lea o le fa'alava o le X-ray o lo'o iai Fa'afitauli ile alfa'aoga taimi,e mana'omia le fetu'una'iga o le paipa i le taimi nei.
5.X-ray Tube Fale Temperature
Aua ne'i pa'i i luga o le fale fa'alava X-ray pe a mae'a le taotoga ona o le maualuga o le vevela.
Taofi le paipa X-ray ina ia mālūlū.
6.Tagata faagaioia
Aʻo leʻi faʻaaogaina,fa'amolemole fa'amaonia le tulaga o le si'osi'omaga o lo'o i totonu ole fa'agaioiga Iimits.
7.So'o se fa'aletonu
Fa'amolemole fa'afeso'ota'i loa SAILRAY,pe afai e iai se faaletonu o le fa'aputuga X-ray ua iloa.
8. Lafoai
O le X-ray tube faʻapotopotoga faʻapea foʻi ma le paipa o loʻo i ai mea e pei o le suauʻu ma uʻamea mamafa lea e faʻafeiloaʻi ai le siʻosiʻomaga ma le faʻaogaina tatau e tusa ai ma tulafono faʻaletulafono a le atunuʻu e tatau ona faʻamaonia. le poto fa'atekinisi mana'omia ma o le a toe fa'afo'i le fa'aputuga fa'a-X-ray mo le lafoai.
Fa'amolemole fa'afeso'ota'i le 'au'aunaga mo lenei fa'amoemoe.
Afai(A) Laititi Fa'asagaga
Afai(A) Nofoaga Tele
Tulaga: Tube Voltage Tolu-Vaega
Ole Malosi ole Stator Fa'asao 50Hz/60Hz
Ia(mA)
t(s)
Ia(mA)
t(s)
IEC60613
Uiga vevela fale
SRMWHX7110A
Fa'afilifiliga Fa'atasi ma Vaega Koluse o le Taulaga
Uaea Feso'ota'i Rotor
Fa'atonuga maualalo: 1pc
Tau: Fa'atalanoaga
Faʻamatalaga Faʻapipiʻi: 100pcs i le pusa poʻo faʻapitoa e tusa ai ma le aofaʻi
Tuuina atu Taimi: 1 ~ 2 vaiaso e tusa ai ma le aofaʻi
Tulaga Totogi: 100% T / T i luma poʻo WESTERN UNION
Tuuina atu Malosiaga: 1000pcs / masina